December 2008 Page 4–13
Chapter 4. Acceptance Tests
4
The LEDs on the “Local” chassis should look
like this:
The LEDs on the “Remote 1” chassis should
look like this:
The LEDs on the “Remote 2” chassis should
look like this:
The LEDs on the “Remote 3” chassis should
look like this:
6. Reconnect the cable to transceiver 1-1 A.
7. Disable transceiver 1-1 B on the “Local”
chassis.
Disconnect the fiber optic cable going to the
receiver of transceiver 1-1 B on the “Local”
chassis.
8. Observe the LEDs on all four chassis.
Table 4-3 shows the LEDs that should be lit
on all four chassis after you complete Step 7.
Amore visual depiction of the LEDs on each
chassis is shown below (the darkened LEDs
are lit, or ON).
The LEDs on the “Local” chassis should look
like this:
The LEDs on the “Remote 1” chassis should
look like this:
The LEDs on the “Remote 2” chassis should
look like this:
Table 4–3. LEDs on all Four Chassis with Transceiver 1-1 B on the “Local” Chassis Disabled.
CHASSIS
LED
LB-A LB-B LSIG-A LSIG-B SWTCH-C HSBOK-C LSIGC LSIGD SWTCH-D HSBOK-D
Local ON ON ON ON
Remote 1 ON ON ON
Remote 2 ON ON ON ON
Remote 3 ON ON ON ON